• Cold Aisle Cabinet
  • Cold Aisle Cabinet

Cold Aisle Cabinet

Comply with ANSI / EIA RS-310-D, IEC297-2 and DIN41491; PART1、DIN41494; PART 7 and GB / T3047.2-92 standards; Compatible with ETSI standard.
  • Cold Aisle Cabinet
Description

Product Description

Designed and developed for modern data centers' requirements for green energy saving, emission reduction, modularization, and intelligent monitoring, they are widely used in financial, government, telecommunications, energy, transportation, medical education, manufacturing and other industries to build, rebuild and expand data centers. Energy efficiency, energy saving up to 30%; strong and weak electrical wiring troughs at the top, closed trajectory opening doors (remote control by remote control card password), fire roof, fire linkage (sound and light alarm, smoke sensor, temperature and humidity sensor), indoor and outdoor units Air conditioners, UPS, rack-mounted precision power distribution cabinets, and data center dedicated cabinets include parallel cabinet components, closed cold aisles, environmental monitoring systems, and KVM.

Features
    • Modular installation, all installations of the entire system are processed into a modular form to the site through the factory, which is convenient for installation;

    • The cooling effect is better than the cooling efficiency of a single cabinet, which improves the installation density of the cabinet equipment and saves space in the computer room;

    • The top cover is opened under the effect of gravity to perform gas fire protection on the cold channel area, which is safe and reliable;

    • Separate hot and cold air, no turbulence, no short circuit, high refrigeration efficiency, save energy cost;

    • Comprehensive computer room management, comprehensive dynamic management, accurate energy efficiency analysis, sound security management, standard network management interface, accurate battery management, and convenient management and maintenance.

Technology

Product characteristics
Channel specifications (width x depth x height) mm Single row: Lx (2200-2400) x (2000-2200), (excluding sunroof flipping height)<15m (including air conditioning)

The cabinet depth supports 1000mm, 1100mm, and 1200mm;

Cabinet height supports 2000mm, 2200mm

Double row: Lx (3200-3600) x (2000-2200), (excluding sunroof flipping height) L<15m (including air conditioning)

Cabinet depth supports 1000mm, 1100mm, and 1200mm

Cabinet height supports 2000mm and 2200mm

Closed channel width supports 1200mm and 1800mm
Number of single module cabinet bodies Single row: 3-24; Double row: 6-40
Installation method

Elevated floor installation can also be directly installed on cement floors

Reliability level Tier II or Tier III or above
Power supply system 380/400/415Vac,50/60Hz,3Ph+N+PE
System protection level IP20
Power supply and distribution system
UPS input voltage 380/400/415Vac,50/60Hz,3Ph+N+PE
UPS rated capacity 20~250kVA
UPS configuration method N、N+1、2N
UPS input power factor Integrated modular UPS: ≥ 0.9, rack mounted modular UPS: 1
UPS overall efficiency ≥95%
Maintenance methods Online hot swapping maintenance
Battery arrangement method Built in or external
PDU installation method Vertical installation at the front/rear of the cabinet
IT cabinet power supply method Mains/oil engine+Mains/oil engine; UPS+UPS; UPS+mains/oil engine
Other C-level lightning protection, 10 inch display screen, and monitoring of branch distribution parameters
Authenticates CCC
Refrigeration system
Air conditioning selection Row level air cooling/chilled water, room level air cooling/chilled water
Refrigeration method Air cooled, chilled water
Power supply method for indoor and outdoor units of air conditioning Separate power supply
Air conditioning installation method Indoor unit elevated floor installation, outdoor unit flat cement floor installation
Compressor type Row level: Variable frequency compressor Room level: Constant frequency compressor
Fan type EC Fan
Air supply mode Row level: Horizontal air supply Room level: Downward air supply
Air conditioning indoor unit size (width x depth x height) mm Row level air conditioning: 300 x 1200 x 2000, 600 x 1200 x 2000, room level air conditioning, see selection table for details
Authenticates CQC Energy Conservation
Monitoring and management system
Functional module Centralized management, access control management, video surveillance, asset management, battery monitoring
Access method Remote web access, local 10 inch touchscreen, mobile app (optional)
Alarm method WeChat alarm, local audio and visual quotation, SMS alarm, email alarm, telephone alarm
Authenticates Software copyright and software testing reports
Cabinet system
Size specifications (width x depth x height) mm (600/800)x(1000/1100/1200)x(2000/2200)
Free space 42U/47U
Authenticates Seismic and load-bearing reports